Page 69 - Glass Machinery Plants & Accessories no. 3-2019
P. 69

efficiency throughout the com-
                                                                               plete forming process.
                                                                                  LumaSense’s solution: High
                                                                               resolution thermal imager with
                                                                               a spectral filter for glass sur-
                                                                               faces and image processing soft-
                                                                               ware for automatic detection of
                                                                               defects.
                                                                                  Customer benefits: General
                                                                               optimization of moulds through
                                                                               visualization of glass wall thick-
                                                                               nesses and localization of thin
                                                                               container walls. Automated
                                                                               mould parameter set-up through
                                                                               optional coupling of the system
                                                                               to the PLC for data correlation.
                                                                               TECHNICAL GLASS
                                                                                  Manufacturing of techni-
                                                                               cal glass is subject to particu-
             toring solution with an open-    achieving the correct gob tem-   larly stringent quality require-
             ended ceramic or inconel tube to   perature prior to the next step in   ments. The only way to achieve
             shield the sensor against interfer-  the process (IS machine).    the desired quality and required
             ing radiation and to ensure the                                   service life of the product is to
             repeatability of readings.       Measuring mould temperature      observe very close tolerances with
               Customer benefits: Reliable     inside the IS machine            regard to material temperatures
             implementation of correct cool-    Challenges: Precise control of   throughout the entire process.
             ing rates. Adjustment of glass   the air flow rate used for blowing   Pyrometers and thermal imag-
             flow rate via its viscosity. Cost   and adjustment of the tempera-  ers from LumaSense Technologies
             reductions through optimized     ture distribution in the water-  are highly accurate temperature
             use of energy.                   cooled mould. This forms the gob   sensors and fulfil all prerequisites
                                              of glass into the desired shape   for successful compliance with
             Measuring temperature gradient in   with the requisite wall thickness.   quality requirements.
             the feeder                         LumaSense’s solution: Portable
               Challenges: Continuous meas-   pyrometer for mobile inspections   Measuring incandescent coils
             urement and control of the mate-  or fixed installed pyrometer.       Challenges: Optimization of
             rial flow. Minimized energy costs   Customer benefits: Optimum      temperature distribution in the
             in the heating process.          uniformity of container wall     incandescent coil.
               LumaSense’s solution:  Proven   thickness. Optimum adjustment      LumaSense’s    solution:  A
             application packages featuring   of coolants.                     fixed-installation thermal imag-
             high measuring accuracy, excellent                                ing system designed to measure
             repeatability and long service lives.   Final check and control of material   very high temperatures on met-
               Customer benefits: Quick       distribution                     als. Real-time thermal imagery
             installation thanks to easy and    Challenges: Save raw materials   of temperature distribution and
             reliable integra¬tion of compo-  with a view to optimizing energy   comprehensive data analysis and
             nents. Optimized use of energy
             and adjustment of glass flow rate.

             Measuring gob temperature
               Challenges: Ensure the desired
             container wall thickness via the
             core temperature of the gob.
               LumaSense’s solution: Rapid
             ratio pyrometer with small meas-
             uring spots.
               Customer benefits: Reliably
   64   65   66   67   68   69   70   71   72   73   74